Buy DIN () Mechanical Structures For Electronic Equipment; Mechanical Structures Of The ,6 Mm (19 Inch) Series; Components On Front . DIN Mechanical structures for electronic equipment; mechanical structures of the ,6 mm (19″)series; components on front panels; mounting. Category:DIN Good pictures. Advanced All images; Featured pictures; Quality images; Valued images; In this category and in In this.

Author: Dukinos Met
Country: Albania
Language: English (Spanish)
Genre: Video
Published (Last): 1 January 2006
Pages: 286
PDF File Size: 18.52 Mb
ePub File Size: 8.55 Mb
ISBN: 692-1-40907-842-4
Downloads: 55019
Price: Free* [*Free Regsitration Required]
Uploader: Zulkizuru

A third common use for rack-mounted equipment is industrial power, control, and automation hardware.

Category:DIN – Wikimedia Commons

The size denotes the width of the faceplate for the installed equipment. Hole spacing is 25 millimetres 0. Rack-mountable equipment is traditionally mounted by bolting or clipping its front panel to the rack. Raised or false floor cooling in server rooms can serve a similar purpose; they permit cooling airflow to equipment through the underfloor space to the underside of enclosed rack cabinets. An enclosed sealed cabinet with forced air fans permits air filtration to protect equipment from dust.

Category:DIN 41494

The next innovation in rack design has been the square-hole rack. The inch dimension includes the edges, or “ears”, that protrude on dim side which allow the module to be fastened to the rack frame with screws.

Computer servers designed for rack-mounting can include a number of extra features to make the server easy to use in the rack:. According to Telcordia Technologies Generic Requirements document GRCORE, during an earthquake, telecommunications equipment is subjected to motions that djn over-stress equipment framework, circuit boards, and connectors. For example, an oscilloscope might be 4U high, and rack-mountable computers are mostly between 1U and 4U high.

George, Chassis Slide MechanismU.

inch rack – Wikipedia

Racks, especially two-post racks, are often secured to the floor or adjacent building structure so as not to fall over. Occasionally, one may see fractional U devices such as a 1. A pair of rails is mounted directly onto the rack, and the equipment then slides into the rack along the rails, which support it. Square-hole racks allow boltless mounting, such that the rack-mount equipment only needs to insert through and hook down into the lip of the square hole. For instance, most optical disc players will not work upside-down because the driving motor mechanism does not grip the disc.

  4TH EDITION PHB2 PDF

End covers are typically secured with either a simple draw latch or a rotary cam “butterfly” latch, named for the shape of the twist handle. Ina durable fiber reinforced plastic inch rackmount case was patented by ECS Composites and became widely used in military and commercial applications for electronic deployment and operation.

Bell Labs Technical Journal. See also Industrial PC.

List of International Electrotechnical Commission standards. To protect equipment from shock and vibration road rack cases use an inner dkn outer case.

Many wall-mounted industrial equipment enclosures have inch rack rails to support mounting of equipment. Rack Cabinet Buying Guide, http: Equipment designed to be placed in a rack is typically described as rack-mountrack-mount instrumenta rack mounted systema rack mount chassissubrackrack mountableor occasionally simply shelf.

In contrast to the “inch world”, ETSI also defined the size of the rack enclosure: A inch rack is a standardized frame or enclosure for mounting multiple electronic equipment modules. Byit was an established standard with holes tapped for screws with alternating spacings of 1.

These cases can be isolated by thick layers of foam or fin use spring-loaded shock mounting.

With the prevalence of inch racks in the Telecoms industry, the same practice is also common, but with equipment having inch and inch brackets available, enabling them to be mounted in existing racks.

Production of clearance-hole racks is less expensive because tapping the holes is eliminated and replaced with fewer, less expensive, cage nuts. A rails kit may include a cable management arm or CMAwhich folds the cables attached dni the server and allows them to expand neatly when the server is dln out, without being disconnected.

Two-post racks provide 41449 vertical posts. The inch rack format has remained constant while the technology that is mounted within it has changed considerably and the set of fields to which racks are applied has greatly expanded. Computer enclosure Mechanical standards Server hardware.

The holes in the posts are arranged vertically in repeating sets of three, with center-to-center separations of 0. The height of the different panels will vary, Equipment can be 4494 either close to its center of gravity to minimize load on its front panelor via the equipment’s front panel holes.

  BUKU PANDUAN HIPNOTIS PDF

The inch rack format with rack-units of 1. Installation and removal of hardware in a square hole rack is very easy and boltless, where the dni of the equipment and small retention clips are all that is necessary to hold the equipment in place. Touring musicians, theatrical productions and sound and light companies use road case racks. In the event of a nut being stripped out ein a bolt breaking, the nut can be easily removed and replaced with a new one.

The fans themselves can be difficult to replace. These cases are marketed to musicians and entertainers for equipment not subject to frequent transportation and rough handling.

Two-post racks are most often used for telecommunication installations. The amount of motion and resulting stress depends on the structural characteristics of the building and framework in which the equipment is contained, and the severity of the earthquake. The earliest repeaters from were installed in ad-hoc fashion on shelves, in wooden boxes and cabinets.

Larger cases typically have wheels for easy transport. The strength required of the mounting posts means they are invariably not merely flat strips but actually a wider folded strip arranged around the corner of the rack. Although open-frame racks are the least expensive, they also expose air-cooled equipment to dust, lint, and other environmental contamination. The dinn of small cases is maintained by the rack rails and the cover seal extrusions alone.

Tapping large numbers of holes that may never sin used is expensive; nonetheless tapped-hole racks are still in use, generally for hardware that rarely changes. The polyethylene shell 4144 not fiberglass reinforced and is not rigid.

The 41944 between the posts is millimetres